Flow and level detection

FLOW METERS - DETECTORS OF LEVEL OR STEP OF FLUID

MEASUREMENT OF FLOW IN LIQUID FLUIDS OR GASES

Different technologies allow to measure the flow of fluids. We highlight electromagnetic flowmeters, thermal flow meters and turbine or paddle flow meters.

ELECTROMAGNETIC FLOWMETER

It works for conductive liquids. It is based on the principle of Faraday's law.
When a current (conductive fluid) flows through a magnetic field, an induced voltage is generated that is detected by the electrodes and is proportional to the velocity of that fluid.
Each flowmeter is made up of the coils that generate the magnetic field and the electrodes.
These flow meters admit large ranges of measurement. All generate signals of type 4-20 mA and pulses.

THERMAL THERMAL FLOWMETER

For gaseous fluids.
It works according to the principle of thermal equilibrium between two sensors.
Maximum temperatures of 70ºC.
Alim 18 ... 36 Vdc.
Galvanically isolated 2 x 4-20 mA outputs and pulses.
Accuracy +/- 1.5% MV + - 0.3fs.
TFT display.
Aluminum box and stainless steel probe. IP 67.
Gas velocity ranges, up to 224 m / s, The flow meter is manufactured according to the type of fluid and duct measurements.
For example, in an internal diameter of 53.1mm (2 "), we have measurement ranges up to 1450 m3 / h.

FLOWMETER FOR TURBINE

For applications where the existing space is reduced and the fluid has a low viscosity.
Its operating principle is to pass the fluid through a microturbine that generates the signal 0-4-20mA or pulsatory.
We offer the flowmeter with different materials and options.

DETECTORES DE NIVEL DE FLUIDOS

We emphasize the capacitives. The probe and the wall of the tank make plates of a capacitor and depending on the level an analog signal is generated (if you want to measure the level with a 4-20 mA signal) or of simple contact as the alarm limit.
There are different options depending on the type of fluid and material in the tank.

NCW CAPACITIVE LEVEL SWITCH

Model NCW - Maximum length 4 m.
Level measurement for viscous products with manual sensitivity adjustment. Principle of capacitive operation.
P max 10 bar.
T max 125º.
Food: 24,110,230 Vac, 18 ... 36 Vdc.
When the fluid touches the sensor, the activation of the relay occurs.

FLOW FOR CAUCAS AND DUCTS TO HALF LOAD (Manning)
FMC8000 / MAN

The touch screen allows a quick parameterization of the values that are required for the flow calculation.
Calculate the water level by Manning's formula.
Protected access to menus by password. Lock with key

FLOWMETERS FOR CONTROL OF STORAGE OR CHANNELS STANDARDIZED

Sludge and sand detector by thermal sensor

ADJUSTABLE SENSITIVITY
1 RELAY 1A 250 V
24 VDC POWER
FOR COMPATIBLE INOX FLUIDS
STATE INDICATION LED
DELAY TO THE CONNECTION